Section 4. USB Communications
19
TERMINATION_CHAR PROPERTY
Property ID: 5
Property Type: Byte
Length: 1 byte
Get Property: Yes
Set Property: Yes
Default Value: 0D (hex) (carriage return)
Description: This property is defined as follows:
mod c c c c c c c
mod 0 – Send c after card data
1 – Send c after each track
c 1-127 – 7 bit ASCII char code
0 – send nothing
This property is stored in non-volatile EEPROM memory so it will not change when the unit is
power cycled. When this property is changed, the unit must be power cycled to have these
changes take effect. If a value other than the default value is desired, it can be set by the factory
upon request.
SS_TK2_7BITS PROPERTY
Property ID: 6
Property Type: Byte
Length: 1 byte
Get Property: Yes
Set Property: Yes
Default Value: 40 (hex) ‘@’
Description: This character is sent as the track 2 start sentinel for cards that have track 2
encoded in 7 bits per character format. If the value is 0 no character is sent. If
the value is in the range 1 – 127 then the equivalent ASCII character will be
sent.
This property is stored in non-volatile EEPROM memory so it will not change when the unit is
power cycled. When this property is changed, the unit must be power cycled to have these
changes take effect. If a value other than the default value is desired, it can be set by the factory
upon request.